Project: Detailed design and manufacture/supply of a
Cathodic Protection (CP) system for some 30kms
of buried in-plant piping within the Eskene West
Onshore Processing Facility (OPF) of the
Kashagan Field Development Programme.
This project had to be designed to cope with
temperatures as low as -35º C.
The CP system was designed based on a close
anode system using canistered mixed metal oxide
(MMO) anodes installed in close proximity to the
buried piping and at 10m spacing along it’s entire
length. A Close Anode CP design works more
effectively than a remote anode system for in-plant
buried piping, as there is a greater reduction in the
loss of CP current to plant earthing systems and
less interference effects on other buried metallic
structures within the plant.
The CP system supplied comprised some 2,650
No. anodes, powered by 134No. 75A/50V dc output
transformer rectifiers through 274No. positive
distribution boxes. Liaising with the five (5)
different Contractors involved in the
construction of the OPF ensured that a
common design philosophy for the CP system
was applied throughout the Plant and that a
commonality of CP equipment was ensured.