Testing & Certification: PolyFlex & PolyFold Pipeline Renewal Systems
The following third-party tests have been performed on PolyFlex™ & PolyFold™ pipeline renewal systems:
|
EN 14409-3, Section 7
|
Test Standard
|
| Hydrostatic strength at 20 degrees C, 100 hrs. |
EN 921/ISO 1167 |
| Hydrostatic strength at 80 degrees C, 1000 hrs. |
EN 921/ISO 1167 |
| Hydrostatic internal pressure strength at 80 degrees C, 165 hrs. |
EN 12201-5/ISO1167 |
| Tensile strength |
EN12201-5/ISO 13953 |
| Geometrical characteristics |
EN ISO 3126 |
|
Additional Testing
|
Test Standard
|
| Notch Test - Determination of resistance to SCG, at 80 degrees C, 500 hrs. |
EN ISO 13479
|
The high density polyethylene pipeline used in PolyFlex™ and PolyFold® is certified by NSF to comply with the requirements of ANSI/NSF Standard 61.
|